  1. This paper does research in distribution network fault section location based on the characteristics of distribution automatic technologies of our country
    本論文根據(jù)我國(guó)配電網(wǎng)自動(dòng)化技術(shù)的特點(diǎn),對(duì)如何確定配電網(wǎng)饋線故障區(qū)域進(jìn)行了研究。
  2. Fault section identification and isolation of distribution network with reclosers and sectionalizers are also talked about . based on load balancing , the way of optimal restoration is disussed
    以安全和負(fù)荷均衡分布為原則,基于等長(zhǎng)鄰接表的數(shù)據(jù)結(jié)構(gòu),建立了故障隔離后受故障影響的健全區(qū)域的優(yōu)化恢復(fù)策略的搜尋方法。
  3. If we can locate the fault section rapidly and accurately when fault occuring , we can isolate the faulut area , resume the power supply for the unaffected area , decrease the power cutted area and bring out great economic benefits
    當(dāng)配電網(wǎng)饋線發(fā)生故障時(shí),要是能夠迅速、準(zhǔn)確地確定故障區(qū)域,就能正確動(dòng)作相關(guān)的電氣設(shè)備來(lái)隔離故障區(qū)域,恢復(fù)對(duì)非故障區(qū)域的供電,減少停電面積,帶來(lái)巨大的經(jīng)濟(jì)效益。
  4. The concept of minimum distribution part ( mdp ) is put forward together with the adjacent table based method to divide a distribution network into several mdps . based on above theory ; a novel way to identify fault sections of a distribution network is presented . algorithm to isolate the fault section with minimum switch operations and identifying of over - tripped switches are discussed
    提出最小配電區(qū)域的概念,并基于等長(zhǎng)鄰接表的數(shù)據(jù)結(jié)構(gòu)建立了最小配電區(qū)域分解的方法,在此基礎(chǔ)上發(fā)展了一種新穎的配電網(wǎng)故障區(qū)域判斷和隔離方法,研究了以最少的開(kāi)關(guān)操作隔離故障區(qū)域的方法和越級(jí)跳閘開(kāi)關(guān)的判斷問(wèn)題,探討了針對(duì)采用重合分段器的配電網(wǎng)故障區(qū)域判斷和隔離問(wèn)題。
  5. It includes four criterions of locating fault point ? “ transient zero sequence current amplitude law ” , “ stable base wave zero sequence current phase law ” , “ stable seventh harmonic zero sequence current phase law ” and “ s injection law ” . pointing out how the law locate the fault point to minimal fault section by applying these criterions gradually . the law will not only make up the blemishes existing in current methods for single - phase fault location in small current grounding system , but also locate the fault point to minimal fault isolating unit on fault line
    該方法通過(guò)將所包含的四個(gè)定位判據(jù)- “暫態(tài)零序電流幅值法” 、 “穩(wěn)態(tài)基波零序電流方向法” 、 “穩(wěn)態(tài)7次諧波零序電流方向法”和“ s信號(hào)注入法” -進(jìn)行有選擇地遞進(jìn)使用,不僅有效彌補(bǔ)了目前已有小電流接地系統(tǒng)單相接地故障選線的缺陷,更將故障定位在故障線路最小故障區(qū)段。
  6. It's difficult to find fault section in a sentence. 用fault section造句挺難的
  7. Fault location techniques are used to pinpoint location of the fault on a tra - nsmission line . transmission line faults must be located accurately to allow maintena - nce crew to arrive at the scene and repair the faulted section as soon as possible , which can relief the burdens of patrol personnel and reduce the revenue losses due to power outage . the accurate fault location alogrithms play an important role in power system safety , economy and reliability . in this paper , diversified fault location algorithms are summarized . according to the principles of algorithms , they can be classified into two categories : impedence based algorithm and traveling wave based algorithm . based on the analysis and comparission of each algorithm , the corresponding merits and app - lication limitations are presented
    精確的故障定位為現(xiàn)場(chǎng)巡線工作人員及時(shí)提供準(zhǔn)確、可靠的信息,減輕人工巡線的負(fù)擔(dān),同時(shí)加快線路的恢復(fù)供電,減少因停電造成的綜合經(jīng)濟(jì)損失,為提高電力系統(tǒng)運(yùn)行的安全性、經(jīng)濟(jì)性和可靠性發(fā)揮重要的作用。本文總結(jié)了現(xiàn)有的各種測(cè)距方法,根據(jù)測(cè)距的原理將其分為阻抗法和行波法兩大類(lèi),對(duì)各種算法的優(yōu)缺點(diǎn)及適用范圍進(jìn)行了分析,在此基礎(chǔ)上提出了一種組合的測(cè)距方案,并對(duì)算法進(jìn)行了仿真分析。
  8. Directed against the distributing fault disposing mode and centralizing fault disposing mode of distribution distribution feeder automation , we use two different research methods respectively . under the distributing fault disposing mode , combined with the technological ameliorate of the applying plc in the switch control department of the urban distribution ring feeder , we design a new voltage - current feeder automation flow executing by recloses and sectionnalizers controlled by plc to locate the distribution feeder fault section
    針對(duì)配電網(wǎng)饋線自動(dòng)化的故障分布處理模式和故障集中控制模式,分別采用了不同的研究方法:在配電網(wǎng)采用故障分布處理的模式下,結(jié)合應(yīng)用于城市手拉手配電環(huán)網(wǎng)的環(huán)網(wǎng)開(kāi)關(guān)柜的技術(shù)改造,設(shè)計(jì)了一種新的電壓-電流型饋線自動(dòng)化模式,利用可編程序控制器( plc )來(lái)控制饋線上的重合器和分段開(kāi)關(guān)來(lái)實(shí)現(xiàn)配電網(wǎng)饋線的故障區(qū)域定位。